ADSS 24 Core Single Mode Outdoor All-Dielectric Self-Support Aerial Cable-G

Application: Communication
Type: Single-mode Fiber
Material Shape: Round Wire
Allowed Lateral Pressure: >1000(N/100mm)
Allowed Tensile Strength: 1000N<10000N
Core: Multicore
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2009

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Customization from Samples
The supplier provides sample based customization services
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (26)

Basic Info.

Model NO.
ADSS
Certification
RoHS, ISO9001
Brand
OEM
Sheath Material
PE
Brand Name
Tw-Scie Fiber Optic Cable or as Required
Product Name
ADSS Fiber Optic Cable
Model Number
ADSS
Fiber Type
Single Mode G652
Number of Conductors
24
Span
80-1000m
Transport Package
Wooden Drum
Specification
ROHS, CE
Trademark
TW-SCIE or OEM
Origin
Guangdong Dongguan
HS Code
854470000
Production Capacity
200km Per Day

Product Description

ADSS 24 Core Single Mode Outdoor All-Dielectric Self-Support Aerial Cable
                                                                                                
1.   GENERAL    
1.1  SCOPE
This specification covers the design requirements and performance standard for the supply of optical fiber cable.
This specification covers the general requirements and performance of cable which
we offered including optical characteristics, mechanical characteristics and geometrical characteristics.
 
Cable type Application
ADSS For Aerial installation
 
1.2 Cable Description
Loose tube cable is a design that has high tensile strength and flexibility in a compact cable size. Our loose tube cable provides excellent optical transmission and physical performance.
1.3 Quality
We ensure a continuing level of quality in our cable products through several quality control programs including ISO 9001 and all the materials have passed REACH and ROHS.
1.4 Reliability
We ensure product reliability through rigorous qualification testing of each product family. Both initial and periodic qualification testing are performed to assure the cable's performance and durability in the field environments.
1.5 Reference
The cable which we offered are designed, manufactured and tested according to international standards as follows:
 
 
IEC 60794-1-1
 
Optical fiber cables. Part 1: Generic specification
 
IEC 60794-1-2
 
Generic specification- basic optical cable test procedures
IEC 60793-3 Outer cables- sectional specification
 
IEC 60794-3-20
Outdoor cables- family specification for optical self-supporting aerial telecommunication cables
EIA/TIA 598 B Color code of fiber optic cables
ITU-T G.650 Definition and test methods for the relevant parameters of single-mode fibers
ITU-T G.652 Characteristics of a single-mode optical fiber cable
ITU-T G.655 Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable
 
 
2. OPTICAL FIBER
· The optical fiber is made of high pure silica and germanium doped silica. UV curable acrylate material is applied over fiber cladding as optical fiber primary protective coating. The detail data of optical fiber performance are shown in the following table.
· G.652D fiber use special spun device successfully controlled the value of PMD, and make sure that it keeps stable in cabling.
· Approved  by  optical  communication  products  ministry  of  quality  supervision  and inspection center, the connection between OFS fiber in and outside is good .The single-end connect-loss won't be over 0.1 dB and the double-end connect-loss is all little than 0.05dB.
· Apply to non-relay communication network. Features: proof test >1%
 G652D In cable
 
 
 
Category
 
 
Description
 
Specifications
 
Before cabling
 
After cabling
 
 
 
 
 
 
 
 
 
 
Optical
Specifications
 
Attenuation @1310 nm
≤0.34 dB/km (max.) ≤0.36 dB/km (max.)
 
Attenuation @1550 nm
≤0.20 dB/km (max.) ≤0.22 dB/km (max.)
 
Attenuation @1625 nm
≤0.23dB/km ≤ 0.25 dB/km
 
Zero Dispersion Wavelength
 
1300~1324 nm
 
Zero Dispersion Slope
≤ 0.092 ps/nm2·km
PMD Link value (M=20cables Q=0.01% )
maximum PMDQ
 
0.2 ps/√km
 
Cable Cutoff Wavelength (λcc)
≤1260 nm
Macro bending Loss
(100 turns; Ф50 mm) @1550 nm
(100 turns; Ф50 mm) @1625 nm
 
≤ 0.05 dB
≤ 0.10 dB
 
Mode Field Diameter @1310 nm
 
9.2±0.4μm
 
 
Dimensional
Specifications
 
Cladding Diameter
 
125 ±0.7μm
 
Core/clad concentricity error
≤0.5μm
 
Cladding Non-Circularity
≤1.0%
Mechanical
Specifications
 
Proof stress
 
≥0.69Gpa
                                  
 
 
 
3. Cable Structure
3.1 Cable Type: ADSS-- Aerial installation cable
 
3.1.1 Dimension and Properties
General properties Unit Nominal value
Fiber count (G.652D) PC 16
Max. No of loose tube/Filler PC 4/2
Max Fiber No. per tube PC 6
Filler material Plastic rod
Loose tube mm 2.2±0.2
material PBT
Water blocking element material Filling compound
Central strength member material FRP
Additional strength member material Aramid yarns
Inner sheath material LDPE black color
mm Min 1.0
Outer sheath material MDPE black color
mm Min 1.8
Outer diameter of Cable mm 12.9±0.2
SPAN M MAX 800
Crush resistance N/100mm 1000/3000
 
 
3.1.2 Working conditions
Temperature range Transport and storage:- 4ºC to +70ºC Min Bending Radius
                  Installation:-10ºC to +60ºC Installation: 20 x OD
Operation:-40ºC to +70ºC    Operation: 10 x OD
Note: 1. the nominal outer diameter may vary by ± 5%.   2. The nominal cable weight may vary by ±10%.                                                                 
 
3.1.3. FIBERS AND TUBE COLOR CODE SCHEME: according to EIA/TIA 598B
Fiber color  Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Tube color Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
 
3.1.4. MAX REEL LENGTH: 3000m / DRUM.
 
 
 
4. TEST REQUIREMENTS
 
The cable is in accordance with applicable standard of cable and requirement of customer.
The following test items are carried out according to corresponding reference.
 
 
No Item  
Reference
 
Tests of Optical Fiber
1 Attenuation coefficient  
IEC 60793-1-40
2 Chromatic dispersion  
IEC 60793-1-42
3 Mode field diameter  
IEC 60793-1-45
4 Cladding diameter  
IEC 60793-1-20
5 Cladding non-circularity  
IEC 60793-1-20
6  
Core/clad concentricity error
 
IEC 60793-1-20
7  
Cable cutoff wavelength
 
IEC 60793-1-44
 
Tests of Outdoor cable (After cabling)
 
 
 
 
1
 
 
 
 
Tensile Test
 
 
 
 
IEC-60794-1-E1
-Max. allowable pulling force: installation tensile; sample length: no less than 50 meters, time: 10 minutes;
- Fiber strain at max. load : max. 0.33 %
No damage to the outer jacket and inner elements. Reversible
 
 
2
 
 
 
Crush test
 
 
 
IEC-60794-1-E3
-Load: short time crush strength, time: 5 minutes, length: 100 mm, number of tests: 3;
No damage to the outer jacket and inner elements.
Reversible
 
 
 
3
 
 
 
Impact test
 
 
 
IEC-60794-1-E4
-Impact energy: 3J , radius: 10.0 mm, impact points: 3
-Number of impacts: 1
-No breakage of the optical fiber,
No splits or cracks in the outer jacket.
-Attenuation increase ≤0.1dB, reversible
 
 
4
 
 
 
Repeated bending test
 
 
 
IEC-60794-1-E6
1m cable length, bending radius: 20 times cable's diameter. 25 cycles, duration of cycle: 2s.
No damage to the outer jacket and inner elements.
Reversible
 
 
5
 
 
Torsion test
 
 
IEC-60794-1-E7
2m cable length, ±180 degrees, 5cycles;
no damage to the outer jacket
-Attenuation increase ≤0.1dB, reversible
 
 
6
 
 
 
Bending test
 
 
 
IEC-60794-1-E11
- Diameter of mandrel: 20xD ,number of turns/helix: 4 number of cycles: 3 ,
No damage to the outer jacket and inner elements
(20 oC). reversible
 
 
 
 
7
 
 
 
 
Temperature cycling test
 
 
 
 
IEC-60794-1-F1
-Temperature step: +20oC →-40oC →+70oC →-40oC
→+70oC →+20oC,
time per each step: 12 hrs, number of cycles: 2 cycles
-they shall be no change in attenuation variation for reference value (the attenuation to be measured before test at +20±3 oC) - reversible
 
8
 
Water penetration test
 
IEC-60794-1-F5
-Water height: 1 m, sample length: 3m, duration of test: 24 hrs.
- No water leakage at the end of the sample
 
 
9
 
 
Drip test
 
 
IEC-60794-1-E14
Three  0.3m  samples  suspended  vertically  in  a climate chamber, raised temperature to +70°C.
no filling compound shall drip from tubes after 24 hr
 
 
 
 
6. PACKING AND DRUM
 
6.1 TW-SCIE cables are packed in carton, coiled on Bakelite & wooden reel. During transportation, right tool should be used to avoid damaging the package, and handle carefully. Cables should be protected from moisture; Cables should be kept away from high temperature condition and spark; Cables should be protected from over bending and crushing; Cables should be protected from mechanical damage.
 

 
6.2 The color of marking is white.( At every meter, the outer sheath of the fiber cable shall be printed )
The inner end of cable is sealed with heat shrinkable end cap to prevent ingress of water and is made available for testing.
The outer end of cable is equipped with heat shrinkable end cap.
 
Outer sheath making legend can be changed according to user's requests.
 
 
6.3 Outdoor cable packing
Bakelite & wooden drum
Strong wooden batten protection
 
ADSS 24 Core Single Mode Outdoor All-Dielectric Self-Support Aerial Cable-G

ADSS 24 Core Single Mode Outdoor All-Dielectric Self-Support Aerial Cable-G
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
91
Year of Establishment
2007-08-27