Item | Description | |
Tensile strength(N) | Long-term | 2500 |
Short-term | 4950 | |
Crush(N/100mm) | Long-term | 1000 |
Short-term | 2000 | |
Min. Bend Radius | Static | 10D |
Dynamic | 20D | |
Temperature Range(ºC) | Operation | -40ºC - +70ºC |
Installation | -10ºC - +50ºC | |
Storage | -40ºC - +70ºC |
Item | Testing | Test Method | Test Result |
1 | Tensile strength IEC 60794-1-E1 |
Long term: 2500N Short term: 4950N Cable length: ≥50m |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
2 | Impact IEC 60794-1-E4 |
Height: 1m Weight: 1kg Impact spot: ≥5 Impact cycle: at lease 3 cycle per spot |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
3 | Repeated Bending IEC 60794-1-E6 |
Bending diameter: 25X the cable outer diameter Applied load: 25kg Bending cycle: 30times Bending speed: 1 cycle per 2s |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
4 | Torsion IEC 60794-1-E7 |
Torsion length: 1m Applied load: 25kg Torsion angle: ±90 or +180 Twist cycle: ≥10 times |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
5 | Water Penetration IEC 60794-1-F5B |
Water height: 1m Cable length: 3m Keeping time: 24hours |
No water leaked from the opposite end of cable |
6 | Temperature IEC 60794-1-F1 |
Temperature step:+20°C->-40°C°C >+70°C->+20°C Keeping time: 24hours per each step Cycle:2times |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
7 | Compound flow IEC 60794-1-E14 |
Sample length: 30cm Temperature: 70ºC±2ºC Keeping time: 24hours |
No compound flow |