Customization: | Available |
---|---|
Application: | Communication |
Type: | Multi-mode Fiber |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Cable type | Application |
GYTA | Aerial & Duct installation cable |
IEC 60794-1-1 |
Optical fiber cables. Part 1: Generic specification |
IEC 60794-1-2 |
Generic specification- basic optical cable test procedures |
IEC 60793-3 | Outer cables- sectional specification |
IEC 60794-3-20 |
Outdoor cables- family specification for optical self-supporting aerial telecommunication cables |
EIA/TIA 598 B | Color code of fiber optic cables |
ITU-T G.650 | Definition and test methods for the relevant parameters of single-mode fibers |
ITU-T G.652 | Characteristics of a single-mode optical fiber cable |
ITU-T G.655 | Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable |
Category |
Description |
Specifications |
|
Before cabling |
After cabling |
||
Optical Specifications |
Attenuation @1310 nm |
≤0.34 dB/km (max.) | ≤0.36 dB/km (max.) |
Attenuation @1550 nm |
≤0.20 dB/km (max.) | ≤0.22 dB/km (max.) | |
Attenuation @1625 nm |
≤0.23dB/km | ≤ 0.25 dB/km | |
Zero Dispersion Wavelength |
1300~1324 nm |
||
Zero Dispersion Slope |
≤ 0.092 ps/nm2·km | ||
PMD Link value (M=20cables Q=0.01% ) maximum PMDQ |
0.2 ps/√km |
||
Cable Cutoff Wavelength (λcc) |
≤1260 nm | ||
Macro bending Loss (100 turns; Ф50 mm) @1550 nm (100 turns; Ф50 mm) @1625 nm |
≤ 0.05 dB ≤ 0.10 dB |
||
Mode Field Diameter @1310 nm |
9.2±0.4μm |
||
Dimensional Specifications |
Cladding Diameter |
125 ±0.7μm |
|
Core/clad concentricity error |
≤0.5μm | ||
Cladding Non-Circularity |
≤1.0% | ||
Mechanical Specifications |
Proof stress |
≥0.69Gpa |
3.1.1 Dimension and Properties | ||
General properties | Unit | Nominal value |
Fiber count | PC | 12 |
Max. No of loose tube/ Fillers | PC | 1/4 |
Fiber No. per tube | PC | 12 |
Loose tube | mm | 2.0±0.2 |
material | PBT | |
Water blocking element | material | Filling compound |
Armour | materia | Corrugated Aluminium tape |
Central strength member | material | Steel wire |
Outer sheath | material | MDPE |
mm | 1.8±0.2 | |
Max. allowable pulling force | N | 1500/600 |
Crush resistance | N/100mm | 1000/300 |
3.1.2 Working conditions | ||
Temperature range | Transport and storage:- 4ºC to +70ºC | Min Bending Radius |
Installation:-10ºC to +60ºC | Installation: 20 x OD | |
Operation:-40ºC to +70ºC | Operation: 10 x OD |
3.1.3. FIBERS AND TUBE COLOR CODE SCHEME: according to EIA/TIA 598B | ||||||||||||
Fiber color | Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
Tube color | Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
No | Item | Reference |
Tests of Optical Fiber |
||
1 | Attenuation coefficient | IEC 60793-1-40 |
2 | Chromatic dispersion | IEC 60793-1-42 |
3 | Mode field diameter | IEC 60793-1-45 |
4 | Cladding diameter | IEC 60793-1-20 |
5 | Cladding non-circularity | IEC 60793-1-20 |
6 | Core/clad concentricity error |
IEC 60793-1-20 |
7 | Cable cutoff wavelength |
IEC 60793-1-44 |
Tests of Outdoor cable (After cabling) | |||
1 |
Tensile Test |
IEC-60794-1-E1 |
-Max. allowable pulling force: installation tensile; sample length: no less than 50 meters, time: 10 minutes; - Fiber strain at max. load : max. 0.33 % No damage to the outer jacket and inner elements. Reversible |
2 |
Crush test |
IEC-60794-1-E3 |
-Load: short time crush strength, time: 5 minutes, length: 100 mm, number of tests: 3; No damage to the outer jacket and inner elements. Reversible |
3 |
Impact test |
IEC-60794-1-E4 |
-Impact energy: 3J , radius: 10.0 mm, impact points: 3 -Number of impacts: 1 -No breakage of the optical fiber, No splits or cracks in the outer jacket. -Attenuation increase ≤0.1dB, reversible |
4 |
Repeated bending test |
IEC-60794-1-E6 |
1m cable length, bending radius: 20 times cable's diameter. 25 cycles, duration of cycle: 2s. No damage to the outer jacket and inner elements. Reversible |
5 |
Torsion test |
IEC-60794-1-E7 |
2m cable length, ±180 degrees, 5cycles; no damage to the outer jacket -Attenuation increase ≤0.1dB, reversible |
6 |
Bending test |
IEC-60794-1-E11 |
- Diameter of mandrel: 20xD ,number of turns/helix: 4 number of cycles: 3 , No damage to the outer jacket and inner elements (20 oC). reversible |
7 |
Temperature cycling test |
IEC-60794-1-F1 |
-Temperature step: +20oC →-40oC →+70oC →-40oC →+70oC →+20oC, time per each step: 12 hrs, number of cycles: 2 cycles -they shall be no change in attenuation variation for reference value (the attenuation to be measured before test at +20±3 oC) - reversible |
8 |
Water penetration test |
IEC-60794-1-F5 |
-Water height: 1 m, sample length: 3m, duration of test: 24 hrs. - No water leakage at the end of the sample |
9 |
Drip test |
IEC-60794-1-E14 |
Three 0.3m samples suspended vertically in a climate chamber, raised temperature to +70°C. no filling compound shall drip from tubes after 24 hr |