Application: | Communication |
---|---|
Type: | Single-Mode or Multi-Mode Fiber |
Connection Structure: | Optical Fiber Cable |
Material Shape: | Round Wire |
Allowed Lateral Pressure: | Short Term 1000n; Long Term 300n |
Allowed Tensile Strength: | Short Term 1500n; Long Term 600n |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Cable Type | GYTA |
Fiber Type | G652D, G657A1 |
Application | Long-distance communication, LAN |
Recommended installation methods | Duct or aerial |
Environment | Outdoor |
Temperature Range | -40ºC to 70ºC |
Item | Description |
Model No | GYTA |
1. Fiber count | 2-30 |
2. Cable Diameter(MM) | 8.4±0.3 |
3. Cable Weight(KG) | 55 |
4. Central Strength member | |
-Material | Steel wire |
5. Loose Tube | |
-Material | PBT |
-Type of filling compound | Jelly |
-No. of loose tube | 1~5 |
6. Filler | |
-Material | PP |
-No. of fillers | 0~4 |
7. Tube Assembly | |
-Tube Layout | 1+5 |
-Stranding type | SZ |
8. Water-blocking system | |
-Material | Filling compound |
9. Core wrap | |
-Material | polyester tape |
10. Armour | |
-Material | Aluminum tape |
-Thickness | 0.22mm |
-Coating material | Plastic |
-Coating thickness | 0.1mm |
11. Outer Sheath | |
-Material | PE |
-Thickness | 1.6mm±0.2mm |
12. Sheath marking | |
-Type of marking | Laser printing |
Item | Description | |
Tensile strength(N) | Long-term | 600 |
Short-term | 1500 | |
Crush(N/100mm) | Long-term | 300 |
Short-term | 1000 | |
Min. Bend Radius | Static | 10D |
Dynamic | 20D | |
Temperature Range(ºC) | Operation | -40ºC - +70ºC |
Installation | -10ºC - +50ºC | |
Storage | -40ºC - +70ºC |
Item | Testing | Test Method | Test Result |
1 | Tensile strength IEC 60794-1-E1 |
Long term: 600N Short term: 1500N Cable length: ≥50m |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
2 | Impact IEC 60794-1-E4 |
Height: 1m Weight: 1kg Impact spot: ≥5 Impact cycle: at lease 3 cycle per spot |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
3 | Repeated Bending IEC 60794-1-E6 |
Bending diameter: 25X the cable outer diameter Applied load: 25kg Bending cycle: 30times Bending speed: 1 cycle per 2s |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
4 | Torsion IEC 60794-1-E7 |
Torsion length: 1m Applied load: 25kg Torsion angle: ±90 or +180 Twist cycle: ≥10 times |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
5 | Water Penetration IEC 60794-1-F5B |
Water height: 1m Cable length: 3m Keeping time: 24hours |
No water leaked from the opposite end of cable |
6 | Temperature IEC 60794-1-F1 |
Temperature step:+20°C->-40°C°C >+70°C->+20°C Keeping time: 24hours per each step Cycle:2times |
Loss change≤0.1dB@1550nm No fiber break and no sheath damage |
7 | Compound flow IEC 60794-1-E14 |
Sample length: 30cm Temperature: 70ºC±2ºC Keeping time: 24hours |
No compound flow |
8 | Sheath high voltage test | On line test DC 12t kV(t-sheath thickness mm) |
No sheath broken down |
Suppliers with verified business licenses